bearer-mbim: don't fail IPv4 connection if IPv4v6 was requested
If we ask for IPv4v6 is requested but the network only grants IPv4, we end up receiving the 'Connect Set' response with nw_error set to 'pdp-type-ipv4-only-allowed'. In this case, we should still succeed the connection attempt and only report the IPv4 info. We therefore change the logic to skip processing the nw_error unless the activation state is reported as ACTIVATED or ACTIVATING.
This commit is contained in:
@@ -570,6 +570,7 @@ connect_set_ready (MbimDevice *device,
|
||||
GError *error = NULL;
|
||||
MbimMessage *response;
|
||||
guint32 session_id;
|
||||
MbimContextIpType ip_type;
|
||||
MbimActivationState activation_state;
|
||||
guint32 nw_error;
|
||||
|
||||
@@ -587,24 +588,30 @@ connect_set_ready (MbimDevice *device,
|
||||
&session_id,
|
||||
&activation_state,
|
||||
NULL, /* voice_call_state */
|
||||
NULL, /* ip_type */
|
||||
&ip_type,
|
||||
NULL, /* context_type */
|
||||
&nw_error,
|
||||
&inner_error)) {
|
||||
if (nw_error) {
|
||||
if (error)
|
||||
g_error_free (error);
|
||||
error = mm_mobile_equipment_error_from_mbim_nw_error (nw_error);
|
||||
} else {
|
||||
/* Report the ip_type we originally requested, since the ip_type
|
||||
* from the response is only relevant if the requested used
|
||||
* MBIM_CONTEXT_IP_TYPE_DEFAULT, which MM never does. Some
|
||||
* devices (K5160) report the wrong type in the response.
|
||||
*/
|
||||
mm_obj_dbg (self, "session ID '%u': %s (IP type: %s)",
|
||||
session_id,
|
||||
mbim_activation_state_get_string (activation_state),
|
||||
mbim_context_ip_type_get_string (ctx->ip_type));
|
||||
/* Report the IP type we asked for and the one returned by the modem */
|
||||
mm_obj_dbg (self, "session ID '%u': %s (requested IP type: %s, received IP type: %s, nw error: %s)",
|
||||
session_id,
|
||||
mbim_activation_state_get_string (activation_state),
|
||||
mbim_context_ip_type_get_string (ctx->ip_type),
|
||||
mbim_context_ip_type_get_string (ip_type),
|
||||
nw_error ? mbim_nw_error_get_string (nw_error) : "none");
|
||||
/* If the response reports an ACTIVATED state, we're good even if
|
||||
* there is a nw_error set (e.g. asking for IPv4v6 may return a
|
||||
* 'pdp-type-ipv4-only-allowed' nw_error). */
|
||||
if (activation_state != MBIM_ACTIVATION_STATE_ACTIVATED &&
|
||||
activation_state != MBIM_ACTIVATION_STATE_ACTIVATING) {
|
||||
if (nw_error) {
|
||||
g_clear_error (&error);
|
||||
error = mm_mobile_equipment_error_from_mbim_nw_error (nw_error);
|
||||
} else if (!error) {
|
||||
error = g_error_new (MM_MOBILE_EQUIPMENT_ERROR,
|
||||
MM_MOBILE_EQUIPMENT_ERROR_GPRS_UNKNOWN,
|
||||
"Unknown error: context activation failed");
|
||||
}
|
||||
}
|
||||
} else {
|
||||
/* Prefer the error from the result to the parsing error */
|
||||
|
Reference in New Issue