readme: convert relative angle-bracket links to named links so they render
This commit is contained in:
parent
a53f273d5b
commit
99dc665ab0
|
@ -26,9 +26,9 @@ WORK SO FAR
|
|||
|
||||
Method 1a is demonstrated. It works on rigid surfaces. See [itm-on-table-drop-30lb-halfway-through.wav](doc/data/itm-on-table-drop-30lb-halfway-through.wav): this was achieved using 181.5 clock single-ended ADC sampling with delay(1) between each sample with no external amplification. The piezo was held in place using an empty water glass.
|
||||
|
||||
On pad: <./doc/data/itm-on-pad-heavy-hit-halfway-through.wav> demonstrates the same setup on a Polish pad on carpet but with a full glass of water.
|
||||
On pad: [itm-on-pad-heavy-hit-halfway-through.wav](doc/data/itm-on-pad-heavy-hit-halfway-through.wav) demonstrates the same setup on a Polish pad on carpet but with a full glass of water.
|
||||
|
||||
<./doc/data/itm-on-pad-tape-big-hit-4clock-1024buffer.wav> and <./doc/data/itm-on-pad-tape-big-hit-4clock-1024buffer.png> shows what we get with a BIG stomp if the sensor is taped to a pad
|
||||
[itm-on-pad-tape-big-hit-4clock-1024buffer.wav](doc/data/itm-on-pad-tape-big-hit-4clock-1024buffer.wav) and [itm-on-pad-tape-big-hit-4clock-1024buffer.png](doc/data/itm-on-pad-tape-big-hit-4clock-1024buffer.png) shows what we get with a BIG stomp if the sensor is taped to a pad
|
||||
it's really hard to get.
|
||||
|
||||
Tried using flat piezos and the L-shaped ones, both behave similarly. Really difficult to get reliable waves.
|
||||
|
@ -40,14 +40,14 @@ Try:
|
|||
- Borrow UW's oscilloscope
|
||||
- Buy a cheapo scope?
|
||||
|
||||
<./doc/data/itm-sandwich-51medianfilt.png> shows results after taping a piezo to a flat surface, loosely setting an acryllic plate on top of it, and then tapping the plate moderately.
|
||||
[itm-sandwich-51medianfilt.png](doc/data/itm-sandwich-51medianfilt.png) shows results after taping a piezo to a flat surface, loosely setting an acryllic plate on top of it, and then tapping the plate moderately.
|
||||
There is median filtering on the device side, plus additional filtering on the PC side.
|
||||
|
||||
Median filter seems to be key. Even without the plate, the device can _detect_ stomps from 4-5 inches away, though not quite as cleanly.
|
||||
Placing the piezo such that half of it is in air seems to help detection. I suspect if the whole platform is oscillating, I want the other end of the piezo somewhere that's more fixed, in order to detect the oscillation of the platform itself. Alternatively, I believe a longer piezo element attached all to the surface could help. A smaller element should still receive everything, but the high frequencies are attenuated. Perhaps then, a HPF could be installed to mitigate this attenuation?
|
||||
Could also try replacing the device-side median filter with a more tuned filter (HPF)
|
||||
|
||||
<./doc/data/itm-pad-drop-weight-3in-away-covered-tape.png>: shows clear signal dropping a 30lb weight near the sensor, even when the sensor is fully attached to the pad. Whole signal is about 5 ms.
|
||||
[itm-pad-drop-weight-3in-away-covered-tape.png](doc/data/itm-pad-drop-weight-3in-away-covered-tape.png): shows clear signal dropping a 30lb weight near the sensor, even when the sensor is fully attached to the pad. Whole signal is about 5 ms.
|
||||
51-median filt device side
|
||||
5000-sample DC removal PC side
|
||||
timescale is accurate
|
||||
|
|
Loading…
Reference in New Issue