
The component loader is a more generic and extensible mechanism of loading components; modules are one type of component... The idea is to make scripts and config files also be components, loaded by plugins that inherit WpComponentLoader
304 lines
9.0 KiB
C
304 lines
9.0 KiB
C
/* WirePlumber
|
|
*
|
|
* Copyright © 2020 Collabora Ltd.
|
|
* @author Julian Bouzas <julian.bouzas@collabora.com>
|
|
*
|
|
* SPDX-License-Identifier: MIT
|
|
*/
|
|
|
|
#include <wp/wp.h>
|
|
#include <pipewire/keys.h>
|
|
#include <pipewire/extensions/session-manager/keys.h>
|
|
|
|
enum {
|
|
STEP_VERIFY_CONFIG = WP_TRANSITION_STEP_CUSTOM_START,
|
|
STEP_ENSURE_ADAPTER_ACTIVATED,
|
|
};
|
|
|
|
struct _WpSiMonitorEndpoint
|
|
{
|
|
WpSessionItem parent;
|
|
|
|
/* configuration */
|
|
WpSessionItem *adapter;
|
|
gchar name[96];
|
|
};
|
|
|
|
static void si_monitor_endpoint_endpoint_init (WpSiEndpointInterface * iface);
|
|
static void si_monitor_endpoint_stream_init (WpSiStreamInterface * iface);
|
|
static void si_monitor_endpoint_port_info_init (WpSiPortInfoInterface * iface);
|
|
|
|
G_DECLARE_FINAL_TYPE(WpSiMonitorEndpoint, si_monitor_endpoint,
|
|
WP, SI_MONITOR_ENDPOINT, WpSessionItem)
|
|
G_DEFINE_TYPE_WITH_CODE (WpSiMonitorEndpoint, si_monitor_endpoint, WP_TYPE_SESSION_ITEM,
|
|
G_IMPLEMENT_INTERFACE (WP_TYPE_SI_ENDPOINT, si_monitor_endpoint_endpoint_init)
|
|
G_IMPLEMENT_INTERFACE (WP_TYPE_SI_STREAM, si_monitor_endpoint_stream_init)
|
|
G_IMPLEMENT_INTERFACE (WP_TYPE_SI_PORT_INFO, si_monitor_endpoint_port_info_init))
|
|
|
|
static void
|
|
si_monitor_endpoint_init (WpSiMonitorEndpoint * self)
|
|
{
|
|
}
|
|
|
|
static void
|
|
si_monitor_endpoint_reset (WpSessionItem * item)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
|
|
/* unexport & deactivate first */
|
|
WP_SESSION_ITEM_CLASS (si_monitor_endpoint_parent_class)->reset (item);
|
|
|
|
g_clear_object (&self->adapter);
|
|
self->name[0] = '\0';
|
|
|
|
wp_session_item_clear_flag (item, WP_SI_FLAG_CONFIGURED);
|
|
}
|
|
|
|
static gpointer
|
|
si_monitor_endpoint_get_associated_proxy (WpSessionItem * item,
|
|
GType proxy_type)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
|
|
if (proxy_type == WP_TYPE_NODE)
|
|
return wp_session_item_get_associated_proxy (self->adapter, proxy_type);
|
|
|
|
return WP_SESSION_ITEM_CLASS (si_monitor_endpoint_parent_class)->
|
|
get_associated_proxy (item, proxy_type);
|
|
}
|
|
|
|
static GVariant *
|
|
si_monitor_endpoint_get_configuration (WpSessionItem * item)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
GVariantBuilder b;
|
|
|
|
/* Set the properties */
|
|
g_variant_builder_init (&b, G_VARIANT_TYPE_VARDICT);
|
|
g_variant_builder_add (&b, "{sv}",
|
|
"adapter", g_variant_new_uint64 ((guint64) self->adapter));
|
|
return g_variant_builder_end (&b);
|
|
}
|
|
|
|
static gboolean
|
|
si_monitor_endpoint_configure (WpSessionItem * item, GVariant * args)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
guint64 adapter_i;
|
|
g_autoptr (GVariant) adapter_config = NULL;
|
|
WpDirection direction = WP_DIRECTION_INPUT;
|
|
const gchar *name = "Unknown";
|
|
|
|
if (wp_session_item_get_flags (item) & (WP_SI_FLAG_ACTIVATING | WP_SI_FLAG_ACTIVE))
|
|
return FALSE;
|
|
|
|
/* reset previous config */
|
|
si_monitor_endpoint_reset (WP_SESSION_ITEM (self));
|
|
|
|
/* get the adapter */
|
|
if (!g_variant_lookup (args, "adapter", "t", &adapter_i))
|
|
return FALSE;
|
|
g_return_val_if_fail (WP_IS_SI_ENDPOINT (GUINT_TO_POINTER (adapter_i)), FALSE);
|
|
self->adapter = g_object_ref (GUINT_TO_POINTER (adapter_i));
|
|
|
|
/* get the adapter direction */
|
|
adapter_config = wp_session_item_get_configuration (self->adapter);
|
|
if (!g_variant_lookup (adapter_config, "direction", "y", &direction)) {
|
|
wp_warning_object (self, "could not get adapter direction");
|
|
return FALSE;
|
|
}
|
|
|
|
/* make sure the direction is always input */
|
|
if (direction != WP_DIRECTION_INPUT) {
|
|
wp_warning_object (self, "only input adapters are valid when configuring");
|
|
return FALSE;
|
|
}
|
|
|
|
/* set the name */
|
|
g_variant_lookup (adapter_config, "name", "&s", &name);
|
|
g_snprintf (self->name, sizeof (self->name) - 1, "monitor.%s", name);
|
|
|
|
wp_session_item_set_flag (item, WP_SI_FLAG_CONFIGURED);
|
|
return TRUE;
|
|
}
|
|
|
|
static guint
|
|
si_monitor_endpoint_activate_get_next_step (WpSessionItem * item,
|
|
WpTransition * transition, guint step)
|
|
{
|
|
switch (step) {
|
|
case WP_TRANSITION_STEP_NONE:
|
|
return STEP_VERIFY_CONFIG;
|
|
|
|
case STEP_VERIFY_CONFIG:
|
|
return STEP_ENSURE_ADAPTER_ACTIVATED;
|
|
|
|
case STEP_ENSURE_ADAPTER_ACTIVATED:
|
|
return WP_TRANSITION_STEP_NONE;
|
|
|
|
default:
|
|
return WP_TRANSITION_STEP_ERROR;
|
|
}
|
|
}
|
|
|
|
static void
|
|
si_monitor_endpoint_activate_execute_step (WpSessionItem * item,
|
|
WpTransition * transition, guint step)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
|
|
switch (step) {
|
|
case STEP_VERIFY_CONFIG:
|
|
if (G_UNLIKELY (!(wp_session_item_get_flags (item) & WP_SI_FLAG_CONFIGURED))) {
|
|
wp_transition_return_error (transition,
|
|
g_error_new (WP_DOMAIN_LIBRARY, WP_LIBRARY_ERROR_INVARIANT,
|
|
"si-monitor-endpoint: cannot activate item without it "
|
|
"being configured first"));
|
|
}
|
|
wp_transition_advance (transition);
|
|
break;
|
|
|
|
case STEP_ENSURE_ADAPTER_ACTIVATED:
|
|
if (!(wp_session_item_get_flags (self->adapter) & WP_SI_FLAG_ACTIVE)) {
|
|
wp_transition_return_error (transition,
|
|
g_error_new (WP_DOMAIN_LIBRARY, WP_LIBRARY_ERROR_INVARIANT,
|
|
"si-monitor-endpoint: cannot activate item without its adapter "
|
|
"being activated first"));
|
|
}
|
|
wp_transition_advance (transition);
|
|
break;
|
|
|
|
default:
|
|
g_return_if_reached ();
|
|
}
|
|
}
|
|
|
|
static void
|
|
si_monitor_endpoint_class_init (WpSiMonitorEndpointClass * klass)
|
|
{
|
|
WpSessionItemClass *si_class = (WpSessionItemClass *) klass;
|
|
|
|
si_class->reset = si_monitor_endpoint_reset;
|
|
si_class->get_associated_proxy = si_monitor_endpoint_get_associated_proxy;
|
|
si_class->configure = si_monitor_endpoint_configure;
|
|
si_class->get_configuration = si_monitor_endpoint_get_configuration;
|
|
si_class->activate_get_next_step =
|
|
si_monitor_endpoint_activate_get_next_step;
|
|
si_class->activate_execute_step =
|
|
si_monitor_endpoint_activate_execute_step;
|
|
}
|
|
|
|
static GVariant *
|
|
si_monitor_endpoint_get_registration_info (WpSiEndpoint * item)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
GVariantBuilder b;
|
|
|
|
g_variant_builder_init (&b, G_VARIANT_TYPE ("(ssya{ss})"));
|
|
g_variant_builder_add (&b, "s", self->name);
|
|
g_variant_builder_add (&b, "s", "Audio/Source");
|
|
g_variant_builder_add (&b, "y", WP_DIRECTION_OUTPUT);
|
|
g_variant_builder_add (&b, "a{ss}", NULL);
|
|
|
|
return g_variant_builder_end (&b);
|
|
}
|
|
|
|
static WpProperties *
|
|
si_monitor_endpoint_get_properties (WpSiEndpoint * item)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
WpProperties *properties;
|
|
g_autofree gchar *description = NULL;
|
|
guint32 endpoint_id = 0;
|
|
|
|
properties = wp_si_endpoint_get_properties (WP_SI_ENDPOINT (self->adapter));
|
|
description = g_strdup_printf ("Monitor of %s",
|
|
wp_properties_get (properties, "endpoint.description"));
|
|
wp_properties_set (properties, "endpoint.description", description);
|
|
|
|
endpoint_id = wp_session_item_get_associated_proxy_id (self->adapter,
|
|
WP_TYPE_ENDPOINT);
|
|
if (endpoint_id)
|
|
wp_properties_setf (properties, PW_KEY_ENDPOINT_MONITOR, "%u", endpoint_id);
|
|
|
|
return properties;
|
|
}
|
|
|
|
static guint
|
|
si_monitor_endpoint_get_n_streams (WpSiEndpoint * item)
|
|
{
|
|
return 1;
|
|
}
|
|
|
|
static WpSiStream *
|
|
si_monitor_endpoint_get_stream (WpSiEndpoint * item, guint index)
|
|
{
|
|
g_return_val_if_fail (index == 0, NULL);
|
|
return WP_SI_STREAM (item);
|
|
}
|
|
|
|
static void
|
|
si_monitor_endpoint_endpoint_init (WpSiEndpointInterface * iface)
|
|
{
|
|
iface->get_registration_info = si_monitor_endpoint_get_registration_info;
|
|
iface->get_properties = si_monitor_endpoint_get_properties;
|
|
iface->get_n_streams = si_monitor_endpoint_get_n_streams;
|
|
iface->get_stream = si_monitor_endpoint_get_stream;
|
|
}
|
|
|
|
static GVariant *
|
|
si_monitor_endpoint_get_stream_registration_info (WpSiStream * self)
|
|
{
|
|
GVariantBuilder b;
|
|
|
|
g_variant_builder_init (&b, G_VARIANT_TYPE ("(sa{ss})"));
|
|
g_variant_builder_add (&b, "s", "default");
|
|
g_variant_builder_add (&b, "a{ss}", NULL);
|
|
|
|
return g_variant_builder_end (&b);
|
|
}
|
|
|
|
static WpSiEndpoint *
|
|
si_monitor_endpoint_get_stream_parent_endpoint (WpSiStream * self)
|
|
{
|
|
return WP_SI_ENDPOINT (g_object_ref (self));
|
|
}
|
|
|
|
static void
|
|
si_monitor_endpoint_stream_init (WpSiStreamInterface * iface)
|
|
{
|
|
iface->get_registration_info =
|
|
si_monitor_endpoint_get_stream_registration_info;
|
|
iface->get_parent_endpoint =
|
|
si_monitor_endpoint_get_stream_parent_endpoint;
|
|
}
|
|
|
|
static GVariant *
|
|
si_monitor_endpoint_get_ports (WpSiPortInfo * item, const gchar * context)
|
|
{
|
|
WpSiMonitorEndpoint *self = WP_SI_MONITOR_ENDPOINT (item);
|
|
|
|
return wp_si_port_info_get_ports (WP_SI_PORT_INFO (self->adapter), "monitor");
|
|
}
|
|
|
|
static void
|
|
si_monitor_endpoint_port_info_init (WpSiPortInfoInterface * iface)
|
|
{
|
|
iface->get_ports = si_monitor_endpoint_get_ports;
|
|
}
|
|
|
|
WP_PLUGIN_EXPORT gboolean
|
|
wireplumber__module_init (WpCore * core, GVariant * args, GError ** error)
|
|
{
|
|
GVariantBuilder b;
|
|
|
|
g_variant_builder_init (&b, G_VARIANT_TYPE ("a(ssymv)"));
|
|
g_variant_builder_add (&b, "(ssymv)", "adapter", "t",
|
|
WP_SI_CONFIG_OPTION_WRITEABLE | WP_SI_CONFIG_OPTION_REQUIRED, NULL);
|
|
|
|
wp_si_factory_register (core, wp_si_factory_new_simple (
|
|
"si-monitor-endpoint", si_monitor_endpoint_get_type (),
|
|
g_variant_builder_end (&b)));
|
|
return TRUE;
|
|
}
|