cdma: try +CSQ? if CSQ fails
Some modems want one, some modems want the other. Try both.
This commit is contained in:
@@ -730,6 +730,8 @@ mm_generic_cdma_update_evdo_quality (MMGenericCdma *self, guint32 quality)
|
||||
}
|
||||
}
|
||||
|
||||
#define CSQ2_TRIED "csq?-tried"
|
||||
|
||||
static void
|
||||
get_signal_quality_done (MMSerialPort *port,
|
||||
GString *response,
|
||||
@@ -740,9 +742,19 @@ get_signal_quality_done (MMSerialPort *port,
|
||||
MMCallbackInfo *info = (MMCallbackInfo *) user_data;
|
||||
char *reply = response->str;
|
||||
|
||||
if (error)
|
||||
info->error = g_error_copy (error);
|
||||
else if (!strncmp (reply, "+CSQ: ", 6)) {
|
||||
if (error) {
|
||||
if (mm_callback_info_get_data (info, CSQ2_TRIED))
|
||||
info->error = g_error_copy (error);
|
||||
else {
|
||||
/* Some modems want +CSQ, others want +CSQ?, and some of both types
|
||||
* will return ERROR if they don't get the command they want. So
|
||||
* try the other command if the first one fails.
|
||||
*/
|
||||
mm_callback_info_set_data (info, CSQ2_TRIED, GUINT_TO_POINTER (1), NULL);
|
||||
mm_serial_port_queue_command (port, "+CSQ?", 3, get_signal_quality_done, info);
|
||||
return;
|
||||
}
|
||||
} else if (!strncmp (reply, "+CSQ: ", 6)) {
|
||||
/* Got valid reply */
|
||||
int quality, ber;
|
||||
|
||||
|
Reference in New Issue