broadband-modem: turn off CNMI <ds> reporting if modem doesn't support it
MM doesn't yet parse the +CNMI=? response and dynamically figure out what indication settings are supported, so add another last-resort CNMI setting for the UMW190 which doesn't support any <ds> at all. And the commands shouldn't be cached, so fix that too.
This commit is contained in:
@@ -5530,17 +5530,17 @@ cnmi_response_processor (MMBaseModem *self,
|
||||
return TRUE;
|
||||
}
|
||||
|
||||
/*
|
||||
* Many devices based on Qualcomm chipsets don't support a <ds> value
|
||||
* of '1', despite saying they do in the AT+CNMI=? response. But they
|
||||
* do accept '2'. Since we're not doing much with delivery status
|
||||
* reports yet, if we get a CME 303 (not supported) error when setting
|
||||
* the message indication parameters via CNMI, fall back to the
|
||||
* Qualcomm-compatible CNMI parameters.
|
||||
*/
|
||||
static const MMBaseModemAtCommand cnmi_sequence[] = {
|
||||
{ "+CNMI=2,1,2,1,0", 3, TRUE, cnmi_response_processor },
|
||||
{ "+CNMI=2,1,2,2,0", 3, TRUE, cnmi_response_processor },
|
||||
{ "+CNMI=2,1,2,1,0", 3, FALSE, cnmi_response_processor },
|
||||
|
||||
/* Many Qualcomm-based devices don't support <ds> of '1', despite
|
||||
* reporting they support it in the +CNMI=? response. But they do
|
||||
* accept '2'.
|
||||
*/
|
||||
{ "+CNMI=2,1,2,2,0", 3, FALSE, cnmi_response_processor },
|
||||
|
||||
/* Last resort: turn off delivery status reports altogether */
|
||||
{ "+CNMI=2,1,2,0,0", 3, FALSE, cnmi_response_processor },
|
||||
{ NULL }
|
||||
};
|
||||
|
||||
|
Reference in New Issue