sim-mbim: increase the timeout for the MBIM_CID_HOME_PROVIDER query
Increase the timeout from 10 seconds to 30 seconds when reading the operator information through the MBIM_CID_HOME_PROVIDER query. We have observed cases where it took more than 12 seconds on a Fibocom L850-GL modem with specific China Unicom SIMs. This timeout was actually the cause of a corruption of the operator name (e.g. returning '@' rather than the real operator name) on the Intel XMM7360 based L850-GL. The following scenario was happening: - the base-sim code sends a first MBIM 'home-provider' query to read the operator identifier. - this query times-out after 10 seconds. - the base-sim immediately sends another MBIM 'home-provider' query to read the operator name. - the modem returns a corrupted operator identifier. Intel helped for the debugging and indicates that when the first query happens, the modem starts reading the SIM files (EF SPN/PNN), apparently it's taking a long time, when it's receives the second query while the first one is not entirely processed, this triggers a bug (in the modem firmware) and returns a corrupted name.
This commit is contained in:
@@ -274,7 +274,7 @@ load_operator_identifier (MMBaseSim *self,
|
||||
message = mbim_message_home_provider_query_new (NULL);
|
||||
mbim_device_command (device,
|
||||
message,
|
||||
10,
|
||||
30,
|
||||
NULL,
|
||||
(GAsyncReadyCallback)load_operator_identifier_ready,
|
||||
task);
|
||||
@@ -335,7 +335,7 @@ load_operator_name (MMBaseSim *self,
|
||||
message = mbim_message_home_provider_query_new (NULL);
|
||||
mbim_device_command (device,
|
||||
message,
|
||||
10,
|
||||
30,
|
||||
NULL,
|
||||
(GAsyncReadyCallback)load_operator_name_ready,
|
||||
task);
|
||||
|